Hardwired Fire Alarm

Hardwired Fire Alarm
Details:
Model: TSS891A-HIR
Power supply: AC 220V-240V 50Hz, with DC 9V alkaline battery back up
Conform to EN14604:2005/AC:2008
Alarm volume: ≥85dB at 3m
Big test button for easy weekly testing
Silence function: Approx.8 mins
Low battery signal alarm
Product life time > 10 years
Wired interconnection up to 40pcs
Automaic compensation design with automatic calibration for accurate sensitivity, suitable for long life operation, lower false alarm rate
RF module, 433MHz, wireless interconnection up to 40pcs
Push base for easy installation
Size: Φ140mm * 44.9mm
Send Inquiry
Description
Send Inquiry
1

 

Products Description

Hardwired Fire Alarm

 

Features:

Power supply: AC 220V-240V 50Hz,with DC 9V alkaline battery back up

Conform to EN14604:2005/AC:2008

Alarm volume: ≥85dB at 3m

Big test button for easy weekly testing

Silence function: Approx.8 mins

Low battery signal alarm

Product life time > 10 years

Wired interconnection up to 40pcs

Automatic compensation design

Push base for easy installation

 

891-HIR

Products video

 

Products detail
2
01

alarm volume

Alarm volume is loud and clear, reaching or surpassing 85dB within a 3-meter radius.

02

time life

Our products have a service life of up to ten years, ensuring long-lasting reliability and peace of mind for our customers.

3
4
03

test button

Easily test your alarm weekly with the convenient test button.

04

Easy Installation

We offer two installation methods: expansion screws or magnetic strips.

5

 

3 Reasons Why Hardwired Smoke Detectors Are Sounding
1. The battery is dead
When the battery is depleted, the smoke detector will alert you of the low battery status by continuously beeping. Simply replacing the battery with a new one can solve this problem.

2. Too much dust
Excessive dust accumulation can trigger false alarms, causing the system to shut down randomly. A thorough cleaning of the inside of the detector can resolve this problem. Before performing this step, be sure to turn off the detector at the circuit box to ensure safety during the cleaning process.

3. The detector is old and defective
Aging and defects are another major cause of noisy systems. Like any other piece of equipment, detectors degrade over time and begin to fail, especially if they have not been replaced for many years. Most smoke detectors have a lifespan of about ten years. After this, their function may begin to deteriorate.

 

Best Selling

913A-1

9V Battery Smoke Alarm

380A-1

3V Battery Smoke Alarm

893-1

Mains Power Smoke Alarm

893-1

Mains Power Heat Alarm

301-1

Standalone Carbon Monoxide Alarm

310-1-

Standalone Carbon Monoxide Alarm

A-4

Wireless Carbon Monoxide Alarm

view more
1

Vaping Detector

view more
our Factory
3
LORENZ Smoke Test Tunnel
1
Assembly Line
4
SMT Workshop
2
Dust-free Workshop
Certifications

 

Certifications

 

BSCI

BSCI

Kitemark

Kitemark

Intertek

Intertek

NF

NF

vds

VdS

CE

CE

 
Exhibitions

 

12

2021

Beijing Exhibition

13

2022

Hannover Messe in Germany

16

2023

The 133rd Canton Fair

15

2023

Spring Hong Kong Exhibition

20

2023

Autumn Hong Kong Exhibition

17

2023

London Exhibition

18

2023

Birmingham Show

19

2023

Dubai Exhibition

Hot Tags: Hardwired Fire Alarm, China, manufacturers, suppliers, factory, 120V Wireless RF Interconnect Smoke Alarm, Nb Iot Wireless Smoke Detector Strobe

Send Inquiry